4 x 2 Standard Codes  

4 x 2  is made up of a 4 digit alarm account code followed by a two digit alarm code. aaaaTP where aaaa is in the hexadecimal  range of  0000 to FFFF and T is in the hexadecimal range of  0 to F, and P is in the hexadecimal range of  0 to F.

While dealers may use any combination of Type "T" and Point "P"  to indicate an alarm condition certain conventions are best observed. When the "T" is represented by a hexadecimal digit (B -F) most receivers and automation systems follow the following convention

"T"ype code 
Condition
"P"oint 
Definition
Test 
X
Periodic Test
1
Fire
X
Fire Alarm zone/point X
2
Panic
X
Panic Alarm zone/point X
3
Burglary
X
Burglary Alarm zone/point X
4
General Alarm
X
General use Alarm zone/point X
5
General Alarm
X
General use Alarm zone/point X
6
General Alarm
X
General use Alarm zone/point X
7
Medical
X
Medical alarm zone/point X
Restore
X
Restore zone/point X
B
Open
X
Opening user  X
C
Close
X
Closing  user  X
D
Cancel 
X
Cancel  user  X
E
Restoral
Restore Zone X
F
Trouble
X
Trouble Zone X


X= a hexadecimal digit in the range of 0 to F